Welcome to the official website of Zhejiang Gaochuan Machinery Technology Co., Ltd!


| Sitemap | RSS | XML

One stop valve Solution Expert

Specializing in the production of various types of valve manufacturers


National consultation hotline:

139-1722-3303

产品banner
Your current location : Home >> Products >> Water conservancy control valve
300X slow-closing muffler check valve

300X slow-closing muffler check valve

  • Classification:Water conservancy control valve
  • Number of visits:second
  • Date of issue:2021-05-21 10:11:57
  • Product overview
  • Performance characteristics
  • technical parameter

  1.300X ease closure Muffler check valve Product Overview :

300X slow closing silencer check valve installation requirements. This product is designed for high-rise and super high-rise buildings. It is used to solve the domestic water and fire-fighting water systems of high-rise buildings. It requires large flow, high sensitivity, low flow resistance, and good non-return sealing effect. 、Occasions requiring no water hammer. This product has the advantages of reasonable design and long service life. Our company’s slow-closing silencing check valve is designed for high-rise and super high-rise buildings. It is used to solve the domestic water and fire-fighting water systems of high-rise buildings. It requires large flow, high sensitivity, low flow resistance, and good non-return sealing effect. Where there is no water hammer. And the product has the advantages of reasonable design and long service life.

2.   Working principle of 300 slow-closing muffler check valve :

When the valve feeds water from the inlet end, the water enters the main valve control room through the micro filter, the needle valve, and the one-way valve, and then drains to the downstream through the ball valve. Because the needle valve opening is smaller than the ball valve opening, that is, the drainage speed of the main valve control room is greater than the water inlet speed, so the pressure in the control room decreases, and the inlet pressure acting on the lower end of the main valve disc opens the main valve to supply water downstream. When the pipeline stops supplying water, if the downstream water starts to flow back, a part of the backflow water enters the main control room through the ball valve. Due to the one-way valve, the backflow water cannot flow out of the main control room, causing the main control room to gradually increase the pressure and slowly close the main valve. . When the pipeline stops supplying water, if the downstream water starts to flow back, a part of the backflow water enters the main control room through the ball valve. Due to the one-way valve, the backflow water cannot flow out of the main control room, causing the main control room to gradually increase the pressure and slowly close the main valve. .

 

3. Performance characteristics of   300X slow-closing muffler check valve:

◆ Novel and reasonable structure, reasonable use of hydraulic principle control theory
◆ Stable and reliable operation, large flow rate
◆ Fast opening and slow closing of the valve disc, no water hammer impact (adjustable closing time
◆ Good non-return sealing effect, long service life
◆ Easy installation and maintenance

 

4.   Installation requirements for 300X slow-closing silencing check valve Basic parameters of slow-closing silencing check valve
Nominal pressure: 1.0-1.6Mpa
Nominal diameter: DN 5 0-DN 600
Applicable medium: clean water
Operating temperature: 0-80 degree
method Blue standard: GB/T17241.6GB/9113
Test standard: GB/T13927 AP1598

 

5.   300 slow-closing muffler check valve installation points

 

A. Pay attention to the direction indicated by the arrow on the valve body during installation. In order to facilitate maintenance, a certain space
should be left around the check valve; B. The stop valve of the corresponding diameter should be installed at the position where the water source can be guaranteed to be cut off when the check valve is repaired ;
C. The muffler check valve must be closed slowly Install the filter.
D. The filter must be installed before the slow-closing muffler check valve.
E The installation time should pay attention to the direction of the arrow on the valve body . In order to facilitate maintenance, a certain space should be left around the check valve.
F. The maintenance should be guaranteed. Install a gate valve of the corresponding diameter at the position where the water source is cut off when the valve is returned.

6. valve body materials and parts reference

Part Name

Part material

Valve body and bonnet

Ductile iron

Valve seat valve disc

Copper alloy

Sealing ring O -ring

Nitrile rubber

Stem

2Cr13

spring

50CrVA

Needle valve

Copper alloy

Ball valve

Copper alloy

Float valve

Copper alloy

Micro filter

stainless steel

 

7. structure drawing: (PN 1.0-2.5MPa):




 Nominal diameter

 Size(mm)




   DN(mm)

L

D

D1

D2

 50

215

165

125

99

 65

235

185

145

118

 80

250

200

160

132

 100

290

220

180

156

 125

325

250

210

184

 150

360

285

240

211

 200

420

340

295

266

 250

450

395

405

350

355

319

 300

510

445

450

400

410

370

 350

645

505

520

460

470

429

 400

720

565

580

515

525

480

480

 450

785

615

640

565

585

582

548

 500

785

670

715

620

650

582

609

 600

910

780

840

725

770

720

780